US Bank Tower
Los Angeles, CA
Waterproofing / Pedestrian Deck Coating / Caulking / Expansion Joints / Lobby Floor Coating / Loading Bay Deck Coating / Below Grade Negative Side Waterproofing / Metal Panel Sealant
Scope of work:
- Expansion Joint Installation with Watson Bowman SafetyFlex
- Deck Coating at exterior decks and cooling tower with Vulkem 350/950/951
- Deck Coating at loading dock area with Pacific Polymers Elasto Deck 6500 VT
- Interior Lobby Sealant with Dow 795 Sealant
- Exterior Metal Panel sealant with Dow 123
- Negative side below grade waterproofing at garage with Xypex
601 S. Figueroa Ave.
Los Angeles, CA
Waterproofing / Pedestrian Deck Coating / Concrete Repairs / Joint Sealant
Scope of work:
- Underslab Waterproofing with WR Grace Preprufe 300 R - 60,000 SF
- Below Grade Insulation with Insulfoam R-Tech
- Removed existing failed deck coating system from all exterior decks and helipad
- Prepared concrete substrate to receive new coating system
- Sealed all cracks with urethane sealant
- Installed Neogard FC rapid curing polyurethane pedestrian traffic coating to all exterior decks and helipad
First Republic Bank Tower, 888 Figueroa Ave.
Los Angeles, CA
Window-Glazing / Repair Failed Systems / Sealant / Waterproof Wall Coating / Roofing / Pavers / Aggregate / Structural Concrete Repair / Pedestrian Deck Coating
Scope of work:
- Removed all existing sealant from the building exterior including windows, joints between stone panels, and metal to stone joints
- Installed Tremco Spectrem 2 silicone sealant to all windows and joints on the entire building
- Owner received a 20 year material warranty
SMBC Manubank
Newport Beach, CA
Roofing / Cool Roof Coating / Flashing / Concrete Repair
Scope of work:
Angelus installed new pedestrian deck coatings on the outdoor patios as part of the new owner's extensive capital improvements.
TCW Tower
Los Angeles, CA
Roofing / Metal Flashing Repair / Heavy Duty Traffic Deck Coating
Scope of work:
Angelus installed new roofing at the top of this 517 ft skyscraper. The work required repairs to the metal flashing. In addition we installed a new heavy duty traffic deck coating on the loading deck.
AON Center
Los Angeles, CA
Restoration / Waterproofing / Deck Coating
Scope of work:
When the Aon Center required restoration, Angelus was called in to repair the damaged concrete and install new waterproof deck coatings.
City National Plaza Towers
Los Angeles, CA
Building Restoration
Scope of work:
This underground shopping mall was converted to underground parking. Angelus was contracted to change the old floor coverings to traffic deck coatings, adding lanes and space markings, and creating the slopes required for underground parking.
Pacific Arts Plaza
Costa Mesa, CA
Expansion-Joints / Joint Sealant / Waterproofing / Deck Coating
Scope of work:
Angelus was contracted to assist wth the major remodeling of the existing deck, patio, and landscape areas with replacement of the expansion joint transitions and renewed traffic and pedestrian deck coatings.
10100 Santa Monica Tower
Century City, CA
Caulk / Sealant / Waterproofing / Traffic Deck Coating / Window-Glazing / Repair Failed Systems
Scope of work:
Angelus was contracted to assist in the process of achieving LEED Platinum accreditation with repair of failed window systems in order to properly seal the window glazing. We also repaired deck systems and installed new coatings.
One Wilshire Tower
Los Angeles, CA
Waterproofing / Deck Coating / Joint Sealant
Scope of work:
Angelus repaired the parking structure with new joint sealants, waterproofing, and traffic deck coatings.
Parsons Corporation
Pasadena, CA
Caulking / Crack Injection-Epoxy & Polyurethane / Waterproofing / Wall Coating / Decorative Cementitious Coating
Scope of work:
We employed epoxy injection to correct the cracks, re-caulked the joints, and applied a decorative cementitious wall coating.
100 Pacifica Tower
Irvine, CA
Restoration / Joint Sealant / Metal Panel Repair
Scope of work:
Angelus restored this high-image office building's distinctive metal panels. The work required their removal and replacement with new joint sealant.